In the Eos commercial energystorage system,long-ife battery cells,new BMS control methods,high-performancePCS,intellienttemperature control system,and active fire control system are integrated into the standardized outdoor cabinets.Eosis designed withthe concept of completely independent electrical and battery components spaces,to enhance thereliability of system temperaturecontrol and fire safety protection.The product is applied in various aplicationscenarios,such as peak cut,new energy consumption,dynamic expansion,and low voltage control of power grid.
Model | TESS-30-100 | TESS-50-100 | TESS-100-215 | TESS-120-241 |
AC (on-grid) | ||||
Apparent power | 33kVA | 55kVA | 110kVA | 132kVA |
Rated power | 30kW | 50kW | 100kW | 120kW |
Rated voltage | 400V | |||
Rated current | 43A | 72A | 144A | 173A |
Voltage range | 360V ~ 440V | |||
Rated frequency | 50/60HZ | |||
THDI | <3% | |||
Power factor | -0.9 lead ~ 0.9 lag | |||
Wire Connection | 3/N/PE | |||
AC input | 33kVA | 55kVA | 110kVA | 132kVA |
AC (off-grid) | ||||
Apparent power | 33kVA | 55kVA | 110kVA | 132kVA |
Rated power | 30kW | 50kW | 100kW | 120kW |
Rated voltage | 400V | |||
Rated current | 43A | 72A | 144A | 173A |
THDU | ≤2% | |||
Rated frequency | 50/60HZ | |||
Overload capacity | 110%for long-term;120%for Imin | |||
DC (battery & PV) | ||||
Max. PV open-circuit voltage | 700V DC | |||
Rated PVPower | 30kWp | 50kWp | 100kWp | 100kWp |
Max.PV Power | 1.1-1.4times rated | |||
PV Voltage Range | 400V ~ 700V DC | |||
Max.PV Current | 60A | 100A | 100A X2 | 100A X2 |
MPPT NO. | 1 | 1 | 2 | 2 |
Battery Voltage Range | 324V~397V | 324V~397V | 696V~852V | 696V~852V |
Available Battery Capacity | 100.35kWh | 100.35kWh | 215.04kWh | 241.92kWh |
Max.Charge Power | 30kW | 50kW | 100kWh | 120kWh |
Max. discharge power | 30kW | 50kW | 100kW | 120kW |
Max. charge current | 92A | 154A | 143A | 172A |
Max. discharge current | 92A | 154A | 143A | 172A |
Basic Parameters | ||||
On/off grid switch function | Assorting | |||
On/off grid switch time | ≤10ms | |||
Noise Level | <65dB(A)@1m | |||
IP protection level | IP54 | |||
Fire protection | Aerosols | |||
Operating Temperature | -25℃-+55℃ | |||
Protection Function | Over /under voltage,Over current,Over/low temperature,SOC too high/lowLowinsulation impedance,Short circuit protection,ete | |||
Cooling | Forced air+SmartAC | |||
Relative Humidity | 0~95%,without condensation | |||
Max.Altitude | 4000m(>2000m derating) | |||
Dimensions(WxDxH) | 1000×1000×2350mm | 1000×1000×2350mm | 1545×1000×2350mm | 1545×1000×2350mm |
Communication | ||||
Display | Touch Screen | |||
Communication interface | RS485 / CAN |