01
04

Three-Phase Residential Hybrid Inverter

Categories:
Residential Energy Storage
Tag:
Residential

Safe and reliable

With such functions as anti-island protection, inverse connection protection of PV input, inverse connection protection of battery input, insulation monitoring, residual current monitoring, AC overcurrent protection, AC overload protection and short-circuit protection

Flexible and friendly

Support the access of diesel generator;

Support the full power discharging and the automatic management of battery charging and discharging;

No external cooling fan designed, allaying the trouble about noise.

Economical and practical

Support multiple operating modes, which is more cost effective;Critical load of UPS protection available without grid.

DataSheet
Parameters

Product model

R6KH3

R8KH3

R10KH3

R12KH3

R15KH3

Protection grade

IP65

Operating temperature

-35~60°C

Relative humidity

0-100%

Working altitude

4,000m (derated above 2,000m)

Cooling type

Natural cooling

Noise

≤25dB

Installation mode

Wall-mounted

EMC

IEC/EN 61000-6-1:2019, IEC/EN 61000-6-2:2019, IEC/EN 61000-6-3:2021, IEN/EN 61000-6-4:2019, IEC/EN 61000-3-2:2019/A1:2021, EN 61000-3-3:2013/A2:2021, IEC/EN 61000-3-11:2019, EN 61000-3-12:2011

On-grid standard

Europe: EN 50549-1:2019/AC:2019, Poland: EN50549-1:2019/Rfg:2016/NC Rfg:2018/PTPiREE:2021, Germany: VDE-AR-N 4105:2018/DIN VDE V 0124-100 (VDE V 0124-100):2020, South Africa: NRS 097-2-1:2017 Edition 2.1, Britain: G99/1-6:2020, Spain: UNE217001:2020/UNE217002:2020/NTS V2.1:2021-07, IEC61727:2004/IEC62116:2014/IEC61683:1999, Hungary: EN50549-1:2019/RFG:2016/Hungary

Safety specification and standard

IEC/EN62109-1:2010,IEC/EN62109-2:2011

Product Interface Parameters

Human-computer interaction

LCD;APP

BMS interface

RS485,CAN

EMS interface

RS485

Electricity meter communication interface

RS485

Support the communication interface

WIFI/GPRS /4G

Battery Interface Parameters

Maximum charging/discharging power

6600W

8800W

11000W

13200W

16500W

Battery voltage range

125~600V

Operating voltage range of battery

150~550V

Maximum charging/discharging current

50A

Rated charging/discharging current

40A

Battery type

Lithium battery and lead-acid cell

DC input parameters (PV side)

Maximum DC input power

9000W

12000W

15000W

18000W

22500W

Maximum DC input voltage

1000V

MPPT voltage range

180~850V

MPPT full-load voltage range

250V~850V

330V~850V

430V~850V

510V~850V

620V~850V

Starting voltage

125V

Maximum input current of a single MPPT

13/13A

13/13A

13/13A

13/13A

20/20A

Maximum short circuit current

16/16A

16/16A

16/16A

16/16A

30/30A

Number of MPPTs

2

Number of MPPTs/maximum number of parallel strings

1/1  1/1

1/1  1/1

1/1  1/1

1/1  1/1

2/2  1/1

Rated input voltage

600V

AC side (grid-connected) parameters

Rated output power

6000VA

8000VA

10000VA

12000VA

15000VA

Maximum output power

6600VA

8800VA

11000VA

13200VA

16500VA

Maximum input power of grid

13200VA

17600VA

22000VA

26400VA

33000VA

Maximum input current of grid

19.1A

25A

31.8A

38.1A

47.6A

Rated output current

8.7A

11.5A

14.4A

17.3A

21.7A

Maximum output current

9.5A

12.7A

15.9A

19.1A

23.8A

Rated grid voltage

380V/400V, 3W+N+PE

Rated grid frequency

50Hz/60Hz

THDI

<2%

AC side (off-grid) parameters

Rated output power

8000VA

8000VA

10000VA

12000VA

15000VA

Maximum output rated power

8800VA

8800VA

11000VA

13200VA

16500VA

Rated output current

8.7A

11.5A

14.4A

17.3A

21.7A

Maximum output current

9.5A

12.7A

15.9A

19.1A

23.8A

Rated output voltage

400V,3W+N+PE

Rated output frequency

50Hz/60Hz

THDu

<2%

Maximum efficiency

97.90%

97.90%

98.20%

98.20%

98.50%

European efficiency

97.20%

97.20%

97.50%

97.50%

97.60%

MPPT efficiency

99.90%

Maximum battery charging/discharging efficiency

97.50%

97.50%

97.50%

97.60%

97.80%

Mechanical parameters

Length, width and thickness

530*560*220mm

Weight

30kg

30kg

31kg

32kg

34kg

More